Onder Ozgener
Solar Energy Institute, Ege University, Bornova, Izmir, Turkey
Leyla Ozgener
Department of Mechanical Engineering Faculty of Engineering, Celal Bayar University, Muradiye, Manisa, Turkey
Download articlehttp://dx.doi.org/10.3384/ecp110571236Published in: World Renewable Energy Congress - Sweden; 8-13 May; 2011; Linköping; Sweden
Linköping Electronic Conference Proceedings 57:1, p. 1236-1240
Published: 2011-11-03
ISBN: 978-91-7393-070-3
ISSN: 1650-3686 (print), 1650-3740 (online)
The main objective of the present study is to investigate the performance characteristics of an underground air tunnel (Earth to Air Heat Exchanger) for greenhouse heating with a 47 m horizontal; 56cm nominal diameter U-bend buried galvanized ground heat exchanger. This system was designed and installed in the Solar Energy Institute; Ege University; Izmir; Turkey. Based upon the measurements were made in the heating mode. The system COP was calculated based on the amount of heating produced by the air tunnel and the amount of power required to move the air through the tunnel.