Conference article

Experimental Study of Long-Wave Night Sky Radiation in Owerri; Nigeria for Passive Cooling Application

N. V. Ogueke
Mechanical Engineering Department, Federal University of Technology, Owerri, Nigeria

C. C. Onwuachu
Mechanical Engineering Department, Federal University of Technology, Owerri, Nigeria

E. E. Anyanwu
Mechanical Engineering Department, Federal University of Technology, Owerri, Nigeria

Download articlehttp://dx.doi.org/10.3384/ecp110572110

Published in: World Renewable Energy Congress - Sweden; 8-13 May; 2011; Linköping; Sweden

Linköping Electronic Conference Proceedings 57:48, p. 2110-2117

Show more +

Published: 2011-11-03

ISBN: 978-91-7393-070-3

ISSN: 1650-3686 (print), 1650-3740 (online)

Abstract

An experimental study to determine the net flux of long wave radiation from the earth’s surface to the atmosphere in Owerri; south east Nigeria for passive cooling applications is presented. The values of the effective sky temperatures are also determined. The experimental rig which is a thermal radiator consists of a flat mild steel plate of dimensions 152.2cm x 38.1cm x 0.3cm coated with high emissivity black paint. A copper tube was used to form five turns and then soldered to the steel plate. Water from a well insulated tank placed at about 0.8 m above the surface of the thermal radiator flowed through the radiator. Thermocouples were strategically inserted on the radiator assembly to measure the plate temperature and water temperature as it flowed along the copper tube. The tests were conducted under the meteorological conditions of ederal University of Technology; Owerri for the period covering March to May; a period often free from the harmattan dust haze. The results revealed that a net long-wave nocturnal cooling power of 66.1 W/m2 is possible. These results are in the same order of magnitude with those obtained elsewhere with similar climatic condition as Owerri; Nigeria.

Keywords

Nocturnal cooling; Experimental; Long wave; Passive cooling; Radiation

References

[1] Ezekwe; C.I. (1986). Nocturnal radiation measurements in Nigeria. Solar Energy 37(1); pp.1 – 6. doi: 10.1016/0038-092X(86)90100-3.

[2] Angstrom; A. (1913). An International Review of Spectroscopy and Astronomical Physics.The Astrophysical Journal; Vol. 37; pp305-317.

[3] Maurer; J. (1887). Measurement of Nocturnal Radiation. Annales de Chime at de Physique; Vol. 20; pp 204-220.

[4] Armenta-Déu; C.; Donaire; T. and Hernando; J. (2003). Thermal analysis of a prototype to determine radiative cooling thermal balance. Renewable Energy 28; pp. 1105 – 1120. doi: 10.1016/S0960-1481(02)00158-1.

[5] Cheikh; H.B. and Bouchair; A. (2004). Passive cooling by evapo-reflective roof for hot dry climates. Renewable Energy 29; pp. 1877 – 1886. doi: 10.1016/j.renene.2003.12.021.

[6] Khedari; J.; Waewsak; J.; Thepa; S. and Hirunlabh; J. (2000). Field investigation of night radiation cooling under tropical climate. Renewable Energy 20; pp. 183 – 193. doi: 10.1016/S0960-1481(99)00104-4.

[7] Bagiorgas; H.S. and Mihalakakou; G. (2008). Experimental and theoretical investigation of a nocturnal radiator for space cooling. Renewable Energy 33; pp. 1220 – 1227. doi: 10.1016/j.renene.2007.04.015.

[8] Dimoudi; A. and Androutsopoulos; A. (2006). The cooling performance of a radiator based roof component. Solar Energy 80; pp. 1039 – 1047. doi: 10.1016/j.solener.2005.06.017.