Woojin Cho
School of mechanical engineering, Hanyang University, Seoul, Republic of Korea
Janghyun Kim
School of mechanical engineering, Hanyang University, Seoul, Republic of Korea
Kwan-Soo Lee
School of mechanical engineering, Hanyang University, Seoul, Republic of Korea
Seung-Kil Son
R&D center, KD Navien co., Republic of Korea
Kwon-Woo Lee
R&D center, KD Navien co., Republic of Korea
Ladda ner artikelhttp://dx.doi.org/10.3384/ecp11057952Ingår i: World Renewable Energy Congress - Sweden; 8-13 May; 2011; Linköping; Sweden
Linköping Electronic Conference Proceedings 57:27, s. 952-959
Publicerad: 2011-11-03
ISBN: 978-91-7393-070-3
ISSN: 1650-3686 (tryckt), 1650-3740 (online)
Selecting a proper capacity of the CHP unit is a complicated problem where energy usage pattern of end users and energy price structures must be considered. Thus; advanced computer simulations are used to predict the proper capacity of the unit; however; certain methods require expensive information such as part load performance of the unit and load profiles of end users. This paper suggests a simple method of predicting proper capacity by presenting analytical equations which calculate annual savings with different capacity of the CHP unit. These equations have merit which can be applied to various conditions by covering the energy usage patterns and energy price structures.
Inga referenser tillgängliga