Konferensartikel

Aspen HYSYS Simulation of CO2 Removal by Amine Absorption from a Gas Based Power Plant

Lars Erik Øi
Telemark University College, Norway

Ladda ner artikel

Ingår i: The 48th Scandinavian Conference on Simulation and Modeling (SIMS 2007); 30-31 October; 2007; Göteborg (Särö)

Linköping Electronic Conference Proceedings 27:8, s. 73-81

Visa mer +

Publicerad: 2007-12-21

ISBN:

ISSN: 1650-3686 (tryckt), 1650-3740 (online)

Abstract

MEA (monoethanol amine) based CO2 removal process have been simulated with the process simulation tool Aspen HYSYS. The thermodynamic properties are calculated with the Peng Robinson and Amines Property Package models which are available in Aspen HYSYS. The adiabatic efficiencies in compressors; gas turbines and steam turbines have been fitted to achieve a total thermal efficiency of 58 % in the natural gas based power plant without CO2 removal. The efficiency is reduced to about 50 % with CO2 removal. The CO2 removal in % and the energy consumption in the CO2 removal plant are calculated as a function of amine circulation rate; absorption column height; absorption temperature and steam temperature. With CO2 removal of 85 %; heat consumption is calculated to 3.7 MJ/kg CO2 removed; close to a literature value of 4.0 MJ/kg CO2.

Nyckelord

Aspen HYSYS; CO2 removal; monoethanol amine; absorption

Referenser

[1] Desideri; U.; Alberto; P. (1999). Performance modelling of a carbon dioxide removal system for power plants; Energy Conversion & Management 40; 1899- 1915.

[2] Freguia; S.; Rochelle; G.T. (2003). Modelling of CO2 Capture by Aqueous Monoethanolamine; AIChE Journal; 49; 1676-1686.

[3] Alie; C.; Backham; P.; Croiset; E.; Douglas; P.L. (2005). Simulation of CO2 capture using MEA scrubbing: a flowsheet decomposition method; Energy Conversion & Management 46; 475-487.

[4] Tobiesen; F.A.; Svendsen; H.F.; Hoff; K.A. (2005). Desorber energy consumption amine based absorption plants. International Journal of Green Energy; 2; 201- 215.

[5] Aspen Plus; AspenTech; Cambridge Mass.; 2006.

[6] Aspen HYSYS 2004.2; AspenTech; Calgary 2007.

[7] Danckwerts; P.V.; Sharma; M.M. (1966). The absorption of Carbon Dioxide into solutions of alkalis and amines; The Chemical Engineer; oct. 244-280.

[8] Versteeg; G.F.; Van Dijck; L.A.J.; Van Swaaij; W.P.M. (1996). On the kinetics between CO2 and alkanolamines both in aqueous and non-aqueous solutions. An overview; Chem. Eng. Comm. 144; 113-158.

[9] Peng; D.; Robinson; D.B. (1976). A New Two- Constant Equation of State; Ind. Eng. Chem. Fundam.; 15 No.1; 59-64.

[10] Kent; R.L.; Eisenberg; B. (1976). Better data for Amine Treating; Hydrocarbon Processing; 55; No.2; 87-90.

[11] Lee; I.J.; Otto; F.D.; Mather; A.E. (1975). Solubility of Mixtures of Carbon Dioxide and Hydrogen Sulfide in 5.0 N Monoethanolamine Solution; J. Chem. Eng. Data; 20; 161-163.

[12] Tomkej; R.A.; Otto; F.D. (1986). Improved Design of Amine Treating Units by Simulation using Personal Computers; World Congress III of Chemical Engineering; Tokyo; Sept. 21-25.

[13] Vamraak; K. (2004). Energiforbruk ved CO2- fjerning fra gasskrafverk; Master Thesis; Telemark University College.

[14] Moholt; B. (2005). Simulering av CO2-fjerning med aminer; Master Thesis; Telemark University College.

[15] Amundsen; T. (2007). CO2-renseanlegg i Aspen HYSYS; Master Project; Telemark University College.

Citeringar i Crossref