Konferensartikel

Robust Calibration of Complex ThermosysPro Models using Data Assimilation Techniques: Application on the Secondary System of a Pressurized Water Reactor

Luis Corona Mesa-Moles
EDF R&D, France

Jean-Philippe Argaud
EDF R&D, France

Audrey Jardin
EDF R&D, France

Amine Benssy
EDF R&D, France

Yulu Dong
EDF R&D, France

Ladda ner artikelhttp://dx.doi.org/10.3384/ecp19157553

Ingår i: Proceedings of the 13th International Modelica Conference, Regensburg, Germany, March 4–6, 2019

Linköping Electronic Conference Proceedings 157:56, s. 8

Visa mer +

Publicerad: 2019-02-01

ISBN: 978-91-7685-122-7

ISSN: 1650-3686 (tryckt), 1650-3740 (online)

Abstract

ThermoSysPro (TSP) is a library for the modeling and simulation of power plants and energy systems. It has been developed by EDF and it is released under open source license. When developing models with TSP it is necessary to ensure that they match reality. In practice, this operation is performed by adjusting the value of the parameters appearing in the model. This major step corresponds to model calibration.

Calibration can be performed through various methods. A classical way to do so with Modelica models is by model inversion. The major inconvenience of this method, in addition of potential convergence problems for complex models, is that it is necessary to have exactly the same number of measurements as parameters to be calibrated, which is not often the case in practice.

This paper shows how data assimilation techniques can robustly be used for calibration of complex TSP models avoiding the inconveniences associated to calibration by model inversion while ensuring an optimal use of the available measurements. A complex TSP model of the secondary loop of a Pressurized Water Reactor (PWR) is considered for this purpose.

Nyckelord

Modelica, ThermoSysPro, ADAO, data assimilation, model calibration, thermal-hydraulics, pressurized water reactor

Referenser

Inga referenser tillgängliga

Citeringar i Crossref