Konferensartikel

Analytical Model and Experimental Validation of the Heat Transfer and the Induced Flow in a PV Cooling Duct in Environmental Conditions

R. Mazón
Thermal and Fluid Engineering Department, Technical University of Cartagena, Murcia, Spain

A. S. Káiser
Thermal and Fluid Engineering Department, Technical University of Cartagena, Murcia, Spain

B. Zamora
Thermal and Fluid Engineering Department, Technical University of Cartagena, Murcia, Spain

J. R. García
Thermal and Fluid Engineering Department, Technical University of Cartagena, Murcia, Spain

F. Vera
Thermal and Fluid Engineering Department, Technical University of Cartagena, Murcia, Spain

Ladda ner artikelhttp://dx.doi.org/10.3384/ecp110572907

Ingår i: World Renewable Energy Congress - Sweden; 8-13 May; 2011; Linköping; Sweden

Linköping Electronic Conference Proceedings 57:29, s. 2907-2915

Visa mer +

Publicerad: 2011-11-03

ISBN: 978-91-7393-070-3

ISSN: 1650-3686 (tryckt), 1650-3740 (online)

Abstract

This paper describes a model to account for the heat transfer and the convective flow induced in the interior of a channel inclined 35° with respect to the horizontal; formed by a photovoltaic panel and an adiabatic plate. The model developed is validated experimentally by measurements made on an experimental prototype. The solar installation consists of two photovoltaic panels integrated with air ducts on the top of a building in southern Spain. The objective is to determine the temperature reached by the photovoltaic module in this configuration. This model considers the processes of heat transfer by radiation and convection on the outside for several atmospheric conditions (wind speed; ambient temperature and incident radiation) and for different geometrical and physical characteristics of the PV cooling duct (plate area; module performance; emission and absorption coefficients). Good agreement has been obtained between the experimental data and the results of this model.

Nyckelord

PV cooling duct; solar experimental facilities; efficiency solar panels

Referenser

[1] J. Khedari; J. Hirunlabh; T. Bunnag; Experimental study of a roof solar collector towards the natural ventilation of new habitations. Energy and Buildings 26; 1997; pp. 159–164. doi: 10.1016/S0378-7788(96)01030-4.

[2] J. Hirunlabh; S. Wachirapuwadon; N. Pratinthong; J. Khedari; New configuration of a roof solar collector maximizing natural ventilation. Building Env. 36; 2001; pp. 383–391. doi: 10.1016/S0360-1323(00)00016-0.

[3] M. Sandberg; B. Moshfegh; Buoyancy-induced air flow in photovoltaic facades. Effect of geometry of the air gap and location of solar cell modules. B. Env. 37; 2002; pp. 211–218 doi: 10.1016/S0360-1323(01)00025-7.

[4] B.J. Brinkworth; R.H. Marshall; Z Ibarah; A validated model of naturally ventilated PV cladding. Solar Energy 69 (1); 2000; pp. 67–81. doi: 10.1016/S0038-092X(99)00076-6.

[5] R. Mazón; JR García; F Vera; A S. Kaiser; B Zamora; Development of an installation to reduce the temperature of photovoltaic modules and improve their efficiency; ICREPQ’10; 2010.

[6] D.L. King; W.E. Boyson; J.A. Kratochvil; Photovoltaic array performance model; Sandia National Laboratories; 87185-0752; 2004.

[7] F. Sarhaddi; S. Farahata; H. Ajama; A. Behzadmehra and M. Mahdavi Adelia; An improved thermal and electrical model for a solar photovoltaic thermal (PV/T) air collector; Applied Energy 87; 2010; pp. 2328-2339. doi: .

[8] B.J. Brinkworth; M. Sandberg; Design procedure for cooling ducts to minimize efficiency loss due to temperature rise in PV arrays; Solar Energy 80; 2006; pp. 89-103. doi: 10.1016/j.solener.2005.05.020.

[9] J.A. Palyvos; A survey of wind convection coefficient correlations for building envelope energy systems´modeling; Applied Thermal Engineering 28; 2008; pp. 801-808. doi: 10.1016/j.applthermaleng.2007.12.005.

[10] B.J. Brinkworth; Estimation of flow and heat transfer for the design of PV cooling ducts; Solar Energy 69; 2000; pp. 413-420. doi: 10.1016/S0038-092X(00)00082-7.

[11] B.J. Brinkworth; Coupling of convective and radiative heat transfer in PV cooling ducts; ASME 124; 2002; pp. 250-255.

Citeringar i Crossref